Pylontech batteries switch from US2000B to US2000C
Up to now we have been delivering the US2000B batteries of Pylontech. However, this version is no longer deliverable and has been replaced by the US2000C. These batteries are virtually identical, but there are 2 differences that must be taken into account:
- The US2000B batteries communicate with Victron devices by means of a VE.CAN type B cable. The US2000C batteries communicate with Victron devices by means of a VE.CAN type A cable.
- As of 9 modules, with the US2000B it is necessary to use an LV-hub. With the US2000C, this only becomes necessary as of 17 modules!
Do you already have a system with US2000B modules and would you like to expand it?
It is no problem to combine US2000C and US2000B modules. But note carefully: always use the US2000C as the master battery with a VE.CAN type A cable.
Do you have more than 8 modules and a combination of US2000B and US2000C?
Then both the master battery and modules 9 to 16 definitely have to be US2000C modules. For modules 2 through 8 you can then use the US2000B batteries.
New Force L2 batteries
In addition, we can also announce that the problems with the Force L2 batteries have been solved. They will be deliverable as of February, but you can already order them now in order to be sure of delivery.