ATEX sight glass fixtures USL05-LED series

The compact explosionproof USL tank inspection lighting is especially designed to illuminate the interior of boilers, tanks, reactors, etc. and fits on all common sight glass fittings. This LED-version has a temperature class T6 and can be used in environments up to 60°C.

USL05EX2304-LED
Show photo

General technical specifications

Housing corrosion-resistant aluminium alloy G-Al Si 10 Mg
Seal O-ring (VITON)
Protection IP67
Lamp LED
Earthing exterior earthing bolt
Cable entry 2m moulded cable 3G1.5mm²
Ambiant temperature -20°C - +60°C
Mounting by means of 1 included central hinged bracket made of stainless steel (M8 fastener)
Sight glass fittings the fittings fit on sight glass fittings from size DN25
Guideline ATEX
Manufacturer Papenmeier - Lumiglas
Suited for
Zone 1 Zone 2
Zone 21 Zone 22

Classification

  • II 2 G Ex d IIC T6 Gb
  • II 2 D Ex tb IIIC T80°C Db

Zone

0 1 2
20 21 22

Ordering data (click on the order reference for more details)

Order refer. Supply voltage Lamp Temperature class
USL05EX2304-LED 230V 4W LED T6

On request

  • 5m or 20m cable